Add to Cart
Tiny Liquid Crystal Polymer Axial Flow Cooling Fan Subminiature Xbox
1504mm DC tiny axial fan , low noise and long life expectancy , is widely used in cooling electronic equipment with micro space such as smartphone , monitoring system , PSP , laptop , tablet PC ,XBOX / PS4 / Wii etc .
Competitive Advantage :
* Qualified, cost effective and easily operated
* Small in shape, have compact structure
* CE, Rohs
* Competitive Pricing
* Keep Investing and Developing In New Products
* The Most Advanced Testing and Measuring Equipment
* On-Time Delivery
*** WE CAN CUSTOMIZE AS YOUR REQUIREMENT ***
Specification and Features
SPECIFICATION | ||
Model Number | MX1504ANH5 | |
Product Name | Ultra-low Power Micro Axial Fan | |
Bearing | Axially-grooved Bearing | |
Rated Voltage | 2.4 V | |
Operating Voltage VDC ) | 2.4 ~ 3.3 V | |
Rated Current | 8 | |
Rotation Speed (RPM) | 5000 | |
Air Flow | 0 . 38 | 0 . 57 |
Static Pressure (mmAq) | 2.14% | 4.73 |
Noise Level | 25 | -35 |
Insulation Resistance | 10MEGA. Ω Min. at 500VDC ( between frame and (+) terminal ) | |
Dielectric Strength | 5mA Max. at 500VAC , 60Hz , One Minute ( between frame and ( +) terminal ) | |
Life Expectancy | 20,000 hours at 45℃ |
Dimensions
Fan Performance Curve
Main Parts and Materials List
Name of Part | Integrated Hall IC | |
Lead wire | UL1571 AWG#32 | |
Cover | SUS 304 | |
Yoke | S.P.C.C. | |
Fan Blade | L.C.P. ( UL94V-0 ) | |
Shaft | SUS 420F | |
Magnet | Rare earth magnet | |
Axial-grooved Bearing | Cu-based composite powder | |
PCB | FR4 | |
Coil | PSW thermosetting copper wire | |
Frame | L.C.P. ( UL94V-0 ) |
Temperature Test
Test Equipment:
A . Temperature & Humidity Chamber
B . Integrated Monitoring Software/Hardware
C . PC
Test conditions:
A . DC voltage setup – 5 . 0V
B . All test samples , No . 1 to No . 4 , are placed horizontally .
C . The electrical functions , appearances and structures of all test samples should remain
normal throughout the test .
Burn-In test
Test Equipment:
A. Power supply
B. UPS system
C. Thermometer & Hydrometer
Test conditions:
A. In open space and under ambient temperature.
B. DC voltage setup – 5.0V
C. Set the test time of continuous operation to 1000 hours.
D. All test samples, No.1 to No.10, are placed horizontally.
E. All test samples should remain the state of continuous rotation throughout the test time to pass
the test.
Drop test
Test conditions:
A.Free falling from an elevation of 120cm of height.
B.The electrical functions, appearances and structures of all test samples should remain normal after
the test.
Working Temperature / Humidity cycle test
Test Equipment:
A . Temperature & Humidity Chamber
B . Integrated Monitoring Software/Hardware
C . PC
Test conditions:
A . Temperature:-10℃ ~ 60 ℃
B . Humidity:0 ~ 98 %
C . DC voltage setup – 5 . 0V
D . All test samples, No . 1 to No . 10, are placed horizontally
E . Running Cycle:2 Times
F . The electrical functions, appearances and structures of all test samples should remain normal
throughout the test .
Stock Temperature / Humidity cycle test
Test Equipment:
A. Temperature & Humidity Chamber
B. Integrated Monitoring Software/Hardware
C. PC
Test conditions:
A. Temperature:-10 ~ 85 ℃
B. Humidity:0 ~ 98 %
C. Running Cycle : 1 Time
D. The electrical functions, appearances and structures of all test samples should remain normal after
the test.
On / Off cycle test
Test Equipment:
A. Integrated Monitoring Software/Hardware
B. PC
Test conditions:
A. Cycle setup:Power On for 20 seconds and then Power Off for 10seconds
Total cycles:10000 times per test sample
B. DC voltage setup – 2.4V
C. All test samples, No.1 to No.4, are placed horizontally
D. The electrical functions, appearances and structures of all test samples should remain normal
throughout the test.
Precautions
1 . Risun Expanse Corp . will not assume responsibility for the performance of the products if the application condition falls beyond the parameters stated forth in this specification .
2 A written request should be submitted to Risun Expanse Corp . prior to written approval if abnormality or deviation from this specification is required .
3 . When storing , handling , or operating this product , please keep any magnetic or ferromagnetic substances off the proximity of this product .
4 . When handling or operating this product , please do not apply pressure to or drop this product , or handle this product by its lead wires .
5 . The correct polarity , Positive ( + ) and Negative ( - ) , has to be clearly identified before connecting this product to the power supply . Please do not connect this product to the power supply with reverse polarity .
6 . This product may not perform normally in corrosive , highly humid , or dusty environment .